== Keypad field ==
{| class="wikitable" border="1"
|-
! style="width: 10em" | Keypad field
! style="width: 40em" | Function
|-
| style="text-align:center" | MODE button<br />
[[File:VTC_a_Mode_Taste.png|100px]]
| This button is intended for later use.
|-
| style="text-align:center" | LED field<br />
[[File:VTC_a_LED_Feld.png|100px]]
| Status display For an explanation, see [[VenCube alpha Quick Guide#Status display|Status display]] below.
|-
| style="text-align:center" | VenTool connection<br />
[[File:VTC_a_Connect.png|100px]]
| A connection to a [[VenToolThin|PC]] or [[VenToolApp|Android device]] is established at this plug using a special connection cable. This makes it possible to read out data and import configurations.
|-
| style="text-align:center" | Button A<br />
[[File:VTC_a_A_Taste.png|100px]]
| is for small cleanings according to HACCP standards.
|-
| style="text-align:center" | Button B<br />
[[File:VTC_a_B_Taste.png|100px]]
| is pressed when product is being refilled at the machine.
|-
| style="text-align:center" | Button C<br />
[[File:VTC_a_C_Taste.png|100px]]
| is for the technician at the machine who is carrying out a repair or inspection. (Press the button once)
|-
| style="text-align:center" | Key D<br />
[[File:VTC_a_D_Taste.png|100px]]
| is for major cleaning according to HACCP standards.
|-
| style="text-align:center" | Key E<br />
[[File:VTC_a_E_Taste.png|100px]]
| is pressed when the cash register is emptied.
|-
| style="text-align:center" | Key F<br />
[[File:VTC_a_F_Taste.png|100px]]
| is pressed to carry out a tube inventory, this is how the coin changer is filled.
|-
|}
== Status display ==
{| class="wikitable" border="1"
|- style="vertical-align:top;"
! style="width: 10em" | Display LED 1
! style="width: 20em" | Meaning/cause
! style="width: 30em" | Elimination
|-
|{{LGn}}
|Vending machine control and credit system OK
|
|- style="vertical-align:top;"
|{{LGnB}} 2x
|Vencube in free sale mode<br>Vending machine control and credit system OK
|
|- style="vertical-align:top;"
|{{LGnB}} 1x {{LRtB}} 1x
|C button pressed when DFC active<br>Fake credit is switched off for flushing
|Press C button again
|- style="vertical-align:top;"
|rowspan="5"|{{LRtB}} 1x
|rowspan="5"|Vencube blocked by machine control or no machine control available
|Switch on the machine's key switch (if available)
|- style="vertical-align:top;"
|Check that the machine is ready for operation
|- style="vertical-align:top;"
|Check/change the machine protocol on the Vencube and machine
|- style="vertical-align:top;"
|Activate the MDB card reader in the machine (not necessary for all machines)
|- style="vertical-align:top;"
|Check the wiring between the machine and the Vencube
|- style="vertical-align:top;"
|{{LGnB}}{{LRtB}}
|VenCube in service mode
|deactivate with "Mode" and "C"
|- style="vertical-align:top;" |rowspan="3"|{{LRtB}} 2x
|rowspan="3"|No credit system available
|Check wiring between Vencube and credit system
|- style="vertical-align:top;"
|Check the credit system protocol settings in Vencube
|- style="vertical-align:top;"
|If a coin changer is connected, check whether it supports Alternative Payout (MDB Level 3)
|- style="vertical-align:top;"
|rowspan="2"|{{LRtB}} 3x
|rowspan="2"|Credit systems blocked by Vencube
|Check whether at least one coin/note has been released
|- style="vertical-align:top;"
|Check the credit system protocol settings in Vencube (must not be set to free sale or deactivated)
|- style="vertical-align:top;"
|rowspan="3"|{{LRt}}
|rowspan="2"|No vending machine controller (VMC) and no credit system available
|Check the setting in the Vencube for the credit system/vending machine protocol
|- style="vertical-align:top;"
|Check the cabling of the vending machine -> Vencube -> credit system
|- style="vertical-align:top;"
|After 3 minutes, LED 1 = 1x red flashing, the credit systems are also switched off and LED 1 lights up red permanently
|see "1x red flashing"
|- style="vertical-align:top;"
|rowspan="2"|{{LGr}}
|no power supply
|Check installation and cable connections
|- style="vertical-align:top;"
|Keyboard defective
|Repair (contact S+M)
|}
{| class="wikitable" border="1"
|- style="vertical-align:top;"
! style="width: 10em" |Display LED 2
! style="width: 20em" |Meaning/Cause
! style="width: 30em" |Remedy
|- style="vertical-align:top;"
|{{LGn}}
|Mobile network OK
|
|- style="vertical-align:top;"
|{{LGnB}} 1x
|Searching for mobile network, no error, please wait!
|
*until LED lights up green (OK)
*until LED lights up red (error)
|- style="vertical-align:top;"
|{{LGnB}} 2x
|Switching mobile network, no error, please wait!
|
*until LED lights up green (OK)
*until LED lights up red (error)
|- style="vertical-align:top;"
|rowspan="3"|{{LRt}}<br>after opening the door
|rowspan="3"|No network found
|Restart Vencube and check whether there is network reception with the door open:
|-
| {{LGn}} '''Yes:''' Change antenna position in or on the machine
|-
| {{LRt}} '''No:''' Change to a suitable antenna, check network
|- style="vertical-align:top;"
|{{LRt}}
|Vencube has no SIM card
|Insert/check SIM card
|- style="vertical-align:top;"
|{{LGr}}
|Modem deactivated
|Activate modem
|}
{| class="wikitable" border="1"
|- style="vertical-align:top;"
! style="width: 10em" | Display LED 1+2
! style="width: 20em" |Meaning/Cause
! style="width: 30em" |Remedy
|-
|{{LGnB}}{{LRtB}} Running light
|Vencube in tube filling mode
|deactivate with "F" key
|}
{| class="wikitable"
| [[File:Hinweis.png|50px]]
| style="background-color:#b1cded; width:35em"|
'''Note:'''<br />
LED 1 and LED 2 light up green/red at the same time or flashing, this indicates a memory error, the VenCube must be replaced.
|}
{| class="wikitable"
| [[File:Hinweis.png|50px]]
| style="background-color:#b1cded; width:35em"|
'''Note:'''<br />
During a software update, LED 1 and LED 2 flash green/red. This can take up to 15 minutes. During this time, the VenCube '''must not''' be switched off.
|}