| == Keypad field ==
| |
|
| |
| {| class="wikitable" border="1"
| |
| |-
| |
| ! style="width: 10em" | Keypad field
| |
| ! style="width: 40em" | Function
| |
| |-
| |
| | style="text-align:center" | MODE button<br />
| |
| [[File:VTC_a_Mode_Taste.png|100px]]
| |
| | This button is intended for later use.
| |
| |-
| |
| | style="text-align:center" | LED field<br />
| |
| [[File:VTC_a_LED_Feld.png|100px]]
| |
| | Status display For an explanation, see [[VenCube alpha Quick Guide#Status display|Status display]] below.
| |
| |-
| |
| | style="text-align:center" | VenTool connection<br />
| |
| [[File:VTC_a_Connect.png|100px]]
| |
| | A connection to a [[VenToolThin|PC]] or [[VenToolApp|Android device]] is established at this plug using a special connection cable. This makes it possible to read out data and import configurations.
| |
| |-
| |
| | style="text-align:center" | Button A<br />
| |
| [[File:VTC_a_A_Taste.png|100px]]
| |
| | is for small cleanings according to HACCP standards.
| |
| |-
| |
| | style="text-align:center" | Button B<br />
| |
| [[File:VTC_a_B_Taste.png|100px]]
| |
| | is pressed when product is being refilled at the machine.
| |
| |-
| |
| | style="text-align:center" | Button C<br />
| |
| [[File:VTC_a_C_Taste.png|100px]]
| |
| | is for the technician at the machine who is carrying out a repair or inspection. (Press the button once)
| |
| |-
| |
| | style="text-align:center" | Key D<br />
| |
| [[File:VTC_a_D_Taste.png|100px]]
| |
| | is for major cleaning according to HACCP standards.
| |
| |-
| |
| | style="text-align:center" | Key E<br />
| |
| [[File:VTC_a_E_Taste.png|100px]]
| |
| | is pressed when the cash register is emptied.
| |
| |-
| |
| | style="text-align:center" | Key F<br />
| |
| [[File:VTC_a_F_Taste.png|100px]]
| |
| | is pressed to carry out a tube inventory, this is how the coin changer is filled.
| |
| |-
| |
| |}
| |
|
| |
| == Status display ==
| |
|
| |
| {| class="wikitable" border="1"
| |
| |- style="vertical-align:top;"
| |
| ! style="width: 10em" | Display LED 1
| |
| ! style="width: 20em" | Meaning/cause
| |
| ! style="width: 30em" | Elimination
| |
| |-
| |
| |{{LGn}}
| |
| |Vending machine control and credit system OK
| |
| |
| |
| |- style="vertical-align:top;"
| |
| |{{LGnB}} 2x
| |
| |Vencube in free sale mode<br>Vending machine control and credit system OK
| |
| |
| |
| |- style="vertical-align:top;"
| |
| |{{LGnB}} 1x {{LRtB}} 1x
| |
| |C button pressed when DFC active<br>Fake credit is switched off for flushing
| |
| |Press C button again
| |
| |- style="vertical-align:top;"
| |
| |rowspan="5"|{{LRtB}} 1x
| |
| |rowspan="5"|Vencube blocked by machine control or no machine control available
| |
| |Switch on the machine's key switch (if available)
| |
| |- style="vertical-align:top;"
| |
| |Check that the machine is ready for operation
| |
| |- style="vertical-align:top;"
| |
| |Check/change the machine protocol on the Vencube and machine
| |
| |- style="vertical-align:top;"
| |
| |Activate the MDB card reader in the machine (not necessary for all machines)
| |
| |- style="vertical-align:top;"
| |
| |Check the wiring between the machine and the Vencube
| |
| |- style="vertical-align:top;"
| |
| |{{LGnB}}{{LRtB}}
| |
| |VenCube in service mode
| |
| |deactivate with "Mode" and "C"
| |
| |- style="vertical-align:top;" |rowspan="3"|{{LRtB}} 2x
| |
| |rowspan="3"|No credit system available
| |
| |Check wiring between Vencube and credit system
| |
| |- style="vertical-align:top;"
| |
| |Check the credit system protocol settings in Vencube
| |
| |- style="vertical-align:top;"
| |
| |If a coin changer is connected, check whether it supports Alternative Payout (MDB Level 3)
| |
| |- style="vertical-align:top;"
| |
| |rowspan="2"|{{LRtB}} 3x
| |
| |rowspan="2"|Credit systems blocked by Vencube
| |
| |Check whether at least one coin/note has been released
| |
| |- style="vertical-align:top;"
| |
| |Check the credit system protocol settings in Vencube (must not be set to free sale or deactivated)
| |
| |- style="vertical-align:top;"
| |
| |rowspan="3"|{{LRt}}
| |
| |rowspan="2"|No vending machine controller (VMC) and no credit system available
| |
| |Check the setting in the Vencube for the credit system/vending machine protocol
| |
| |- style="vertical-align:top;"
| |
| |Check the cabling of the vending machine -> Vencube -> credit system
| |
| |- style="vertical-align:top;"
| |
| |After 3 minutes, LED 1 = 1x red flashing, the credit systems are also switched off and LED 1 lights up red permanently
| |
| |see "1x red flashing"
| |
| |- style="vertical-align:top;"
| |
| |rowspan="2"|{{LGr}}
| |
| |no power supply
| |
| |Check installation and cable connections
| |
| |- style="vertical-align:top;"
| |
| |Keyboard defective
| |
| |Repair (contact S+M)
| |
| |}
| |
|
| |
| {| class="wikitable" border="1"
| |
| |- style="vertical-align:top;"
| |
| ! style="width: 10em" |Display LED 2
| |
| ! style="width: 20em" |Meaning/Cause
| |
| ! style="width: 30em" |Remedy
| |
| |- style="vertical-align:top;"
| |
| |{{LGn}}
| |
| |Mobile network OK
| |
| |
| |
| |- style="vertical-align:top;"
| |
| |{{LGnB}} 1x
| |
| |Searching for mobile network, no error, please wait!
| |
| |
| |
| *until LED lights up green (OK)
| |
| *until LED lights up red (error)
| |
| |- style="vertical-align:top;"
| |
| |{{LGnB}} 2x
| |
| |Switching mobile network, no error, please wait!
| |
| |
| |
| *until LED lights up green (OK)
| |
| *until LED lights up red (error)
| |
| |- style="vertical-align:top;"
| |
| |rowspan="3"|{{LRt}}<br>after opening the door
| |
| |rowspan="3"|No network found
| |
| |Restart Vencube and check whether there is network reception with the door open:
| |
| |-
| |
| | {{LGn}} '''Yes:''' Change antenna position in or on the machine
| |
| |-
| |
| | {{LRt}} '''No:''' Change to a suitable antenna, check network
| |
| |- style="vertical-align:top;"
| |
| |{{LRt}}
| |
| |Vencube has no SIM card
| |
| |Insert/check SIM card
| |
| |- style="vertical-align:top;"
| |
| |{{LGr}}
| |
| |Modem deactivated
| |
| |Activate modem
| |
| |}
| |
|
| |
| {| class="wikitable" border="1"
| |
| |- style="vertical-align:top;"
| |
| ! style="width: 10em" | Display LED 1+2
| |
| ! style="width: 20em" |Meaning/Cause
| |
| ! style="width: 30em" |Remedy
| |
| |-
| |
| |{{LGnB}}{{LRtB}} Running light
| |
| |Vencube in tube filling mode
| |
| |deactivate with "F" key
| |
| |}
| |
|
| |
| {| class="wikitable"
| |
| | [[File:Hinweis.png|50px]]
| |
| | style="background-color:#b1cded; width:35em"|
| |
| '''Note:'''<br />
| |
| LED 1 and LED 2 light up green/red at the same time or flashing, this indicates a memory error, the VenCube must be replaced.
| |
| |}
| |
|
| |
| {| class="wikitable"
| |
| | [[File:Hinweis.png|50px]]
| |
| | style="background-color:#b1cded; width:35em"|
| |
| '''Note:'''<br />
| |
| During a software update, LED 1 and LED 2 flash green/red. This can take up to 15 minutes. During this time, the VenCube '''must not''' be switched off.
| |
| |}
| |
|
| |
| [[Category:Index]]
| |