The device is assembled by the customer.
Proceed as follows during assembly:
Open the machine.
Turn off the power to the machine.
Determine the optimal installation position: Place the VENCUBE as close as possible to the machine controls and payment systems. Make sure that the controls are easily accessible. Note the cable length.
Glue the base plate (holder) and screw it. (Image 1)
If gluing is not possible, the assembly click holder must be screwed diagonally to the designated points in the machine with at least 2 screws1). The screw heads must be complete
Sit flush and must not protrude. 1) Hardened countersunk self-drilling screw, ∅ 3.5 according to DIN 7504
Clip the VENCUBE into the base plate. (Image 2)
Remove the machine controls cover.
The machine must be voltage-free!
Disconnect all existing payment systems (1, 2) from the machine control. (Image 3)
Connect the cables from the VENCUBE:
Connect the (MDB) master connection (3) from the VENCUBE to the vending machine control. (Image 4)
Connect the (MDB) slave port (4) to all existing payment systems (5). If necessary, use a Y-cable. (Image 5)
If possible, glue the antenna (6) behind a plastic cover. (Image 6)
Route the antenna cable.
Lay all cables professionally with cable ties.
Never use the existing door switch of the machine, this can destroy the Vencube.
Always connect the door switch as closer to plug 1 with the Vencube. Use connector "COM" and connector "NO" from the switch.
Image 1Image 3Image 5
Image 2Image 4Image 6
Vencube Commissioning
Turn on the machine.
If necessary, adjust the Vencube using the Ventool.
If necessary, configure the machine control and the payment systems. You can find information on this in the wiki!
Wait until both LEDs turn green.
Close the door.
Test the machine by making a trial vend with change.
Open the door again.
Enter the data for VENSOFT (serial number, machine number).
Perform a cash withdrawal by pressing the “E” button on the Vencube until you hear a beep.
Close the door.
Commissioning is complete.
Sielaff FS 2020 AutomatDoor switch angleDoor switch angle with switch
Installation location of the VencubeScrewed angle door switchBuilt-in door switch angle
Initial commissioning
After the VMC is switched on for the first time with the Vencube connected, there is increased data exchange between the controller and the Vencube. As a result, the VMC cannot be operated for up to ten minutes, or only very slowly, and coin acceptance and payout can be disrupted at the same time. After the waiting time, the machine will work again without any problems.
Settings of the VMC
VMC Auster SUE
Make the following settings in the patch menu and check them in the installation menu and make additional settings there if necessary.
The patch menu is reached via the service menu (M-8-E) by entering 99M 55M.
Patch menu settings M - 8 - E 99M 55M
Einstellung
Option
ALT.PAYOUT
enabled
TUBECOUNT
Coin Mech contr.
MIXED PAYMENT
allowed
MDB-comp.mode
B.Pract.
SAVE SETTINGS
yes
After pressing the "E" key
"done" stands for confirmation
in the display!
Settings in the installation menu M - 7 - E
Einstellung
Option
> KREDITSYSTEM
KRED.KONFIG.
MAN.EINSTELLEN
> GELDWECHSLER
TUBENZÄHLER
Münzwechsler
ALT. PAYOUT
ein
TUBENLEERMELDUNG
ggf. Anpassen
> KARTENSYSTEM
MISCHZAHLUNG
ein
MIXED PAYM.PRICE
Barpreisliste
MDB-comp.mode
Best Practice
MDB ITEM NUMBERS
Hexadezimal
Software version / FTL
Display of the software status in the service menu: M - 8 - E - 21 - L