Vencube in connection with a HVMC-100 VMC

Aus Vensolutions
Zur Navigation springen Zur Suche springen

Operating the Vencube with a Höfer HVMC-100 controller

Requirement

For MDB operation of the Vencube on an HVMC controller, the use of an EPROM with the software version:
HVMC 100-CC Version 1.38EUR (2Mbit)
is absolutely necessary! EPROMs larger than 1Mbit cannot be used in the first series of HVMC controllers, which is why only a BDV Vencube can be used here. All subsequent HVMC controllers are equipped for MDB operation with a Vencube after a software update. These controllers can be distinguished by the label printed on them.

HVMC 100

Print: HVMC 100:

Vencube can only be connected under BDV!

HVMC 100-1/-2/-3

Print: HVMC 100-1/-2/-3

MDB operation with a Vencube is possible after a software update!

  • The software version HVMC 100 Version 1.38 EUR must be used.
  • Switch the control to MDB operation: ⇒ Set DIP switch 2 to OPEN.
  • In the menu, set C8.A with Display card amount

After a possible EPROM replacement, the control must be initialized and reconfigured; all previous data will be lost.

Connecting the Vencube with MDB interface

Preparation

  1. Switch off the machine control (press the machine main switch or remove ST7)
  2. Check the EPROM version:
    HVMC 100-CC version 1.00 must be replaced with
    HVMC 100-CC version 1.38!
    Note the installation direction, the notch of the EPROM and the IC socket is important and not the EPROM sticker.
  3. Insert the Vencube into the MDB interface of the control.
  4. Connect MDB payment systems to the Vencube via MDB.
  5. Switch on the machine.

Initialize control

  1. The following should now appear on the display:
    Eprom exchange -> Initialize!
  2. Set dip switches 1+5 to the edge of the board and 2-4 to OPEN (control initialization)!
  3. Press the star button
  4. The following is shown on the LC display: Clear ??
  5. Now press selection button 5 on the machine.
  6. Now set all dip switches to OPEN again.
  7. Wait until Help! F6 appears on the display.
  8. Either continue with the section "Switching to a two-line display" or continue with the section "Switching to MDB operation".

Switching to a two-line display

Function of the selection buttons in the service menu
Select 1 Back from the submenu
Select 2 Step forward (up) in the menu
Select 3 Step back (down) in the menu
Select 4 Call (enter) the selected menu item
Select 5 Special functions (delete) Clear
  1. If a two-line display is installed, the display setting must be changed to 2 lines with 16 characters.
    Important: With a one-line LC display, this point can be skipped!
  2. Press the star button for more than 5 seconds:
    Clr ERR! appears (keep holding it down)
    and wait for the ServMenu display and then release.
    The following: C 0. .
  3. Press selection button 2: You will be asked for a password! PW ????
    Password is 4231, press the relevant selection buttons and after entering it the following appears: C 1. .
  4. Press selection button 4 and press selection button 2 several times to go to the menu item C 1.C..
  5. Use selection button 4 to call up the setting 1Zl.8St.
    and use selection button 2 to set it to two lines. 2Zl.16St
  6. Use the selection key 1 to go back until C 0. . is shown on the display.
  7. Press the star button
  8. Wait until Help! F6 is shown on the display.

Switch to MDB operation

  1. Activate MDB credit system: Set dip switch 1, 3-5 to OPEN and dip switch 2 to the edge of the board.
  2. If required, activate the empty lamp control for GP: Set dip switch 4 to the edge of the board.
  3. Press the star button
    After the control system has booted up, one of the two displays should appear on the display.
    either: No change! or: Hello

Set machine

Function of the selection buttons in the service menu
Select 1 Back from the submenu
Select 2 Step forward (up) in the menu
Select 3 Step back (down) in the menu
Select 4 Call (enter) the selected menu item
Select 5 Special functions (delete) Clear
  1. Press the star button for more than 5 seconds:
    Clr ERR! appears (keep holding)
    and wait for the ServMenu display and release.
    The following : C 0. .
  2. Press selection key 2: You will be asked for a password! PW ????
    Password is 4231, press the respective selection keys and after entering the following appears: C 1. .
  3. Now configure the machine in the following menu items:
  4. #C1.3 Set the date and time
    1. C1.6 Set the number of slots
    2. C1.1 Assign the selection keys to the outputs
    3. C6 Price setting
    4. Important!: C8 Set credit system setting in menu item C8.A to "show with card amount"!
  5. Use button 1 to reach menu item C 0. .
  6. Press the star button.
  7. Switch off the machine, wait a few seconds and switch it back on.
  8. Test the sale.

Vencube einstellen via Ventoolwin

Programmbereich Funktion
HVMC
Im Feld HVMC einen Haken setzen!
Diese Einstellung ist für die korrekte Funktion der Meldung "Kein Wechselgeld" in Verbindung mit einer HVMC 100 Steuerung. Diese Funktion nur mit einer HVMC Steuerung benutzen!
Das EVA Feld CCRBLC wird auf 1 gesetzt: MA5*CCRBLC*1
Grenze "Kein Wechselgeld" bzw. Meldung "Kein Wechselgeld"
Im Menü C 8.8der Steuerung und im Vencube den Wert identisch einstellen.
Downloads
Hier bieten wir Ihnen eine Anleitung zur Installation des Vencubes an einer HVMC-Steuerung zum Download an.