Coinco

Coinco Global

image root cause rectification
Coinco Global coin changer MDB level from coin changer is not level 3
  • Set MDB level to 3 with all options.
  • In Coinco Global: Set A009 from 0 to 1.
  • Changer must be set to Alternate Payout.

Display value in the changer at address A009 must be changed from 0 to 1:

  • Press A and D simultaneously for 1 second.
  • Message "----" / "Fill" alternating with "AbCd" or "Full" is displayed.
  • Press Button-B (increase) to cycle through the different addresses.
  • After reaching address A009, press the C button to display the current setting status.
  • Set value must be changed from 0 to 1. (B button)
  • Now press the C button again to save the selection made.
  • Press key-A to return to address mode. Now press the A button again to exit the display mode.

If the VenCube is still making noise, the vending machine must be switched off for at least 15 seconds. After switching on again, the problem is then solved.

Coges

Coges Aeterna

image root cause rectification
Unfortunately I don't have a picture today! VenCube generates ticking noises.

Convert the changer as described in the procedure
6.7 Management Remainder Remaining device MDB (The change issue is automatically controlled by the coin switching device)
6.15 Setup MDS
6.15.7 Status MDS set standard or complete

A more detailed description of the setting will follow at a later date.

CPI/mei

CPI Gryphon

Picture Cause Rectification
CPI Gryphon Münzwechsler MDB level of the coin changer is not level 3
  1. Press menu key.
  2. Press E for settings.
  3. Select key E for machine settings.
  4. Select key A for MDB.
  5. Use the E key to select MDB Level 3.
  6. Save with F key.
  7. Press the Menu button 5 times to exit the menu. The coin changer will then restart.

The vending machine must be turned off and back on. Please wait a few seconds before turning it back on.

mei CF 690

image root cause rectification
Cashflow 690 Münzwechsler MDB level from coin changer is not level 3

The coin changer must be converted to MDB Level 3 with all extras:

  1. Hold the "Yellow button" on the coin validator for two seconds until Prices appears on the display.
  2. Use the "B button" (press once) to go to Settings and confirm with the "A button" .
  3. Now the display shows MDB Config.: Active and by pressing the '"A-key" again MDB Version is called up.
  4. The display continues to scroll and pressing the "A button" again shows (level).

There are three settings:
Change with the 'B-key'!
- Level 2
- Level 3 No Extras
- Level 3 All extras.

  1. Select the setting MDB Level 3 All Extras and confirm with the '"A-Key".
  2. Exit the settings menu by pressing the "yellow button".
  3. If the VenCube is still ticking, the vending machine must be switched off once.
    Please wait a few seconds before switching it on again.

Attention:
There are 2x MDB Level 3, please note the running text in the display.

mei CF 7400

image root cause rectification
mei CF7400 Münzwechsler MDB level from coin changer is not level 3
The CF7400 cannot be switched in the field. In this case, the coinchanger must be replaced.

mei CF 7900

image root cause rectification
mei CF7900 Münzwechsler MDB level from coin changer is not level 3
Setting
  1. Press and hold the yellow button on the coin validator for 3 seconds until Prices is shown on the display.
  2. Press the D button 3x until Automation Options appears on the display.
  3. Press yellow button 1x for MDB Options and press yellow button again for Change. optimal..
  4. Press the D button once for Level and confirm with the yellow button.
  5. Then press the D button until Level 3 is displayed and confirm with yellow.
  6. Now press the C button until you exit the menu.

Then restart the vending machine. Please wait a few seconds before turning it back on.

mei CF 8xxx

image root cause rectification
mei CF8200 Münzwechsler MDB level from coin changer is not level 3
The level 3 setting applies to all four variants of the 8000 series.
  • CF 8200
  • CF 8250
  • CF 8500
  • CF 8550
Setting
  1. Press and hold the yellow button on the coin validator for 3 seconds until Prices is shown on the display.
  2. Press the D button 3x until Automation Options appears on the display.
  3. Press yellow button 1x for MDB Options and press yellow button again for Change. optimal..
  4. Press the D button once until Level is displayed.
  5. Select Level menu with yellow and select Level 3 using the D or E button and confirm with yellow.
  6. Then press the C button until you exit the menu.

Then restart the vending machine. Please wait a few seconds before turning it back on.

CPI/NRI

NRI Currenza C2

Image Root cause Rectification
NRI Suzo Happ Currenza MDB level from coin changer is not level 3
  1. Press menu key.
  2. Select button E for settings.
  3. Step down with the B button to -Other settings and confirm again with E (OK).
  4. Press button B until -MDB-Level- is displayed. Confirm again with E.
  5. Now you can change the level with the A and B keys.
  6. Level 3 must be set.
  7. Confirm with E (OK) and exit the menu with the Menu button (press twice).

The vending machine must be switched off and on again once. Please wait a few seconds before turning it back on. If the device does not have a display with buttons, the change can be made with the HENRI module.

SuzoHapp

SuzoHapp Currenza C2

Image Root cause Rectification
NRI Suzo Happ Currenza MDB level from coin changer is not level 3
  1. Press menu key.
  2. Select button E for settings.
  3. Step down with the B button to -Other settings and confirm again with E (OK).
  4. Press button B until -MDB-Level- is displayed. Confirm again with E.
  5. Now you can change the level with the A and B keys.
  6. Level 3 must be set.
  7. Confirm with E (OK) and exit the menu with the Menu button (press twice).

The vending machine must be switched off and on again once. Please wait a few seconds before turning it back on. If the device does not have a display with buttons, the change can be made with the HENRI module.