MDB level from coin changer is not level 3
|
- Set MDB level to 3 with all options.
- In Coinco Global: Set A009 from 0 to 1.
- Changer must be set to Alternate Payout.
Display value in the changer at address A009 must be changed from 0 to 1:
- Press A and D simultaneously for 1 second.
- Message
"----" / "Fill" alternating with "AbCd" or "Full" is displayed.
- Press Button-B (increase) to cycle through the different addresses.
- After reaching address A009, press the C button to display the current setting status.
- Set value must be changed from 0 to 1. (B button)
- Now press the C button again to save the selection made.
- Press key-A to return to address mode. Now press the A button again to exit the display mode.
If the VenCube is still making noise, the vending machine must be switched off for at least 15 seconds. After switching on again, the problem is then solved.
|