Erstinbetriebnahme
|
After the VMC is switched on for the first time with the Vencube connected, there is increased data exchange between the controller and the Vencube. As a result, the VMC cannot be operated for up to ten minutes, or only very slowly, and coin acceptance and payout can be disrupted at the same time. After the waiting time, the machine will work again without any problems.
|
Einstellungen der Steuerung
Steuerung Auster HG 2540
|
Note:
These VMC all have MDB interfaces, the Vencube should therefore also be operated directly via MDB without adapter boards or cable harnesses and not via BDV master cable. Depending on which cashless payment system is connected to the Vencube, a BDV or MDB slave cable is to be used here. For coin changers and bill readers, always MDB is preferable.
|
|
Note:
Depending on the type of VMC and the software version of the VMC, not all setting options may be available, and the points that are not available can then be skipped. It may also be possible that the setting items have a German or English name, or that the texts are displayed somewhat differently.
|
Folgende Einstellungen im Patchmenü vornehmen und im Installationsmenü überprüfen und ggf. dort zusätzlich einstellen.
Das Patchmenü wird über das Servicemenü (M-8-E) mit der Eingabe 99M 55M erreicht.
Einstellungen im Patchmenü
M - 8 - E 99M 55M Menüstruktur wie in
|
| Einstellung
|
Option
|
| ALT.PAYOUT
|
enabled
|
| TUBECOUNT
|
Coin Mech contr.
|
| MIXED PAYMENT
|
allowed
|
| MDB-comp.mode
|
B.Pract.
|
| SAVE SETTINGS
|
yes
Nach betätigen der "E"-Taste
steht "done" als Bestätigung
im Display!
|
|
|
Einstellungen im Installationsmenü
M - 7 - E Menüstruktur wie in
|
| Einstellung
|
Option
|
| > KREDITSYSTEM
|
KRED.KONFIG.
|
MAN.EINSTELLEN
|
| > GELDWECHSLER
|
TUBENZÄHLER
|
Münzwechsler
|
| ALT. PAYOUT
|
ein
|
| TUBENLEERMELDUNG
|
ggf. Anpassen
|
| > KARTENSYSTEM
|
MISCHZAHLUNG
|
ein
|
| MIXED PAYM.PRICE
|
Barpreisliste
|
| MDB-comp.mode
|
Best Practice
|
|
Softwarestand / FTL
Anzeige des Softwarestandes im Servicemenü: M - 8 - E - 21 - L
| Software
|
Patchmenü
|
FTL geeignet
|
 |
 |
|
Steuerung Auster HG M32
|
Note:
These VMC all have MDB interfaces, the Vencube should therefore also be operated directly via MDB without adapter boards or cable harnesses and not via BDV master cable. Depending on which cashless payment system is connected to the Vencube, a BDV or MDB slave cable is to be used here. For coin changers and bill readers, always MDB is preferable.
|
|
Note:
Depending on the type of VMC and the software version of the VMC, not all setting options may be available, and the points that are not available can then be skipped. It may also be possible that the setting items have a German or English name, or that the texts are displayed somewhat differently.
|
Folgende Einstellungen im Patchmenü vornehmen und im Installationsmenü überprüfen und ggf. dort zusätzlich einstellen.
Das Patchmenü wird über das Servicemenü (M-8-E) mit der Eingabe 99M 55M erreicht.
Einstellungen im Patchmenü
M - 8 - E 99M 55M Menüstruktur wie in
|
| Einstellung
|
Option
|
| ALT.PAYOUT
|
enabled
|
| TUBECOUNT
|
Coin Mech contr.
|
| MIXED PAYMENT
|
allowed
|
| MDB-comp.mode
|
B.Pract.
|
| SAVE SETTINGS
|
yes
Nach betätigen der "E"-Taste
steht "done" als Bestätigung
im Display!
|
|
|
Einstellungen im Installationsmenü
M - 7 - E Menüstruktur wie in
|
| Einstellung
|
Option
|
| > KREDITSYSTEM
|
KRED.KONFIG.
|
MAN.EINSTELLEN
|
| > GELDWECHSLER
|
TUBENZÄHLER
|
Münzwechsler
|
| ALT. PAYOUT
|
ein
|
| TUBENLEERMELDUNG
|
ggf. Anpassen
|
| > KARTENSYSTEM
|
MISCHZAHLUNG
|
ein
|
| MIXED PAYM.PRICE
|
Barpreisliste
|
| MDB-comp.mode
|
Best Practice
|
|
|
Kreditanzeige bei Münzeinwurf sehr träge:
- Unter: Menü ⇒ Installation ⇒ Kartensystem 2 deaktivieren
- Unter: Menü ⇒ Installation ⇒ Sondereinstellung C,
die MDB Pollingrate auf 100ms oder 50ms setzen!
|
|
Die MDB Pollingrate nur in ausgewählten Einzelfällen anpassen!
|
|
Die Tabelle zeigt die Bitmaske für die gewünschten Einstellungen, bitte passend einstellen.
| 01
|
Bei Kaltwasserprodukten wird der Becherpreis zu 0.00
|
| 02
|
IR Auslesung/Konfiguration nur aktiv, wenn in Menüebene betreten (kein Menü ausgewählt)
|
| 04
|
Alle Fehlermeldungen im Klartext nach außen geben
|
| 08
|
Druckmeßdose alt (0.5 .. 4.5V
|
| 16
|
Wassermangelerkennung über die Messturbine deaktiviert (Espressogeräte)
|
| 32
|
BARISTA: Bei Erreichen Milchreinigungszeit (Def. = 36h) werden die Milchprodukte nicht ausser Betrieb genommen.
|
| 64
|
MDB-Pollingrate auf 100ms verkürzen
|
| 128
|
MDB-Pollingrate auf 50ms verkürzen, gewinnt gegenüber 64
|
|
Softwarestand / FTL
Anzeige des Softwarestandes im Servicemenü: M - 8 - E - 21 - L
| Software
|
Patchmenü
|
FTL geeignet
|
 |
 |
|
Problemlösungen
Übersicht der Problemlösungen