Installation instructions

File User manual Vencube beta currently only in German
Download link BA_Vencube_beta_032020.pdf

Vencube assembly and commissioning

Mount the Vencube

The device is assembled by the customer.
Proceed as follows during assembly:

  • Open the machine.
  • Turn off the power to the machine.
  • Determine the optimal installation position:
    Place the VENCUBE as close as possible to the machine controls and payment systems.
    Make sure that the controls are easily accessible.
    Note the cable length.
  • Glue the base plate (holder) and screw it. (Image 1)

If gluing is not possible, the assembly click holder must be screwed diagonally to the designated points in the machine with at least 2 screws1). The screw heads must be complete Sit flush and must not protrude.
1) Hardened countersunk self-drilling screw, ∅ 3.5 according to DIN 7504

  • Clip the VENCUBE into the base plate. (Image 2)
  • Remove the machine controls cover.

The machine must be voltage-free!

  • Disconnect all existing payment systems (1, 2) from the machine control. (Image 3)
  • Connect the cables from the VENCUBE:
  • Connect the (MDB) master connection (3) from the VENCUBE to the vending machine control. (Image 4)
  • Connect the (MDB) slave port (4) to all existing payment systems (5). If necessary, use a Y-cable. (Image 5)
  • If possible, glue the antenna (6) behind a plastic cover. (Image 6)
  • Route the antenna cable.
  • Lay all cables professionally with cable ties.

Never use the existing door switch of the machine, this can destroy the Vencube.

Always connect the door switch as closer to plug 1 with the Vencube.
Use connector "COM" and connector "NO" from the switch.

Image 1
Image 3
Image 5
Image 2
Image 4
Image 6

Vencube Commissioning

  • Turn on the machine.
  • If necessary, adjust the Vencube using the Ventool.
  • If necessary, configure the machine control and the payment systems.
    You can find information on this in the wiki!
  • Wait until both LEDs turn green.
  • Close the door.
  • Test the machine by making a trial vend with change.
  • Open the door again.
  • Enter the data for VENSOFT (serial number, machine number).
  • Perform a cash withdrawal by pressing the “E” button on the Vencube until you hear a beep.
  • Close the door.
  • Commissioning is complete.


  • Place Vencube as close as possible to the vending machine control and payment systems.
  • Glue or screw the base plate into the machine. If the base plate is glued, please press it firmly into place without the Vencube.
  • Power down the machine and disconnect all existing payment systems from the vending machine control.
  • Connect the MDB master port from the VenCube to the vending machine control.
  • Connect the MDB slave port to all existing payment systems. Y-cables should be used for additional MDB slave connections.
  • Install door switch.

Never use the existing door switch of the machine, this can destroy the Vencube.

Always connect the door switch as closer to plug 1 with the Vencube.
Use connector "COM" and connector "NO" from the switch.

Please check that the switch operates properly just before the lock plate is flush with the machine.

HG CVS 500
Door switch angle
Door switch angle with switch
Vencube installation location
Screwed angle door switch
Built-in door switch angle

Initial commissioning

After the VMC is switched on for the first time with the Vencube connected, there is increased data exchange between the controller and the Vencube. As a result, the VMC cannot be operated for up to ten minutes, or only very slowly, and coin acceptance and payout can be disrupted at the same time. After the waiting time, the machine will work again without any problems.

VMC settings

VMC Auster HG 2540

Note:
These VMC all have MDB interfaces, the Vencube should therefore also be operated directly via MDB without adapter boards or cable harnesses and not via BDV master cable. Depending on which cashless payment system is connected to the Vencube, a BDV or MDB slave cable is to be used here. For coin changers and bill readers, always MDB is preferable.

Note:
Depending on the type of VMC and the software version of the VMC, not all setting options may be available, and the points that are not available can then be skipped. It may also be possible that the setting items have a German or English name, or that the texts are displayed somewhat differently.

Make the following settings in the patch menu and check them in the installation menu and make additional settings there if necessary.

The patch menu is reached via the service menu (M-8-E) by entering 99M 55M.

Settings in the patch menu
M - 8 - E 99M 55M
Menu structure as in
Settings Options
ALT.PAYOUT enabled
TUBECOUNT COIN MECH contr.
MIXED PAYMENT allowed
MDB-comp.mode B.Pract.
SAVE SETTINGS yes

After pressing the "E" key
"done" stands for confirmation
in the display!

Settings in the installation menu
M - 7 - E
Menu structure as in
Settings Options
> CREDIT SYSTEM CRED. CONFIG. MAN.CONFIG.
> COIN MECHANISM TUBE COUNT by COINMECH
ALT. PAYOUT on
TUBES EMPTY INFO A
> CARD READER MIXED PAYM. on
MIXED PAYM.PRICE cash price
MDB-comp.mode Best Practice

Note:
The previously made settings must be checked again after a software update of the VMC.

Software version / FTL

Display of the software status in the service menu: M - 8 - E - 21 - L

Software Patch menu FTL suitable Comment

VMC Auster HG M32

Note:
These VMC all have MDB interfaces, the Vencube should therefore also be operated directly via MDB without adapter boards or cable harnesses and not via BDV master cable. Depending on which cashless payment system is connected to the Vencube, a BDV or MDB slave cable is to be used here. For coin changers and bill readers, always MDB is preferable.

Note:
Depending on the type of VMC and the software version of the VMC, not all setting options may be available, and the points that are not available can then be skipped. It may also be possible that the setting items have a German or English name, or that the texts are displayed somewhat differently.

Make the following settings in the patch menu and check them in the installation menu and make additional settings there if necessary.

The patch menu is reached via the service menu (M-8-E) by entering 99M 55M.

Settings in the patch menu
M - 8 - E 99M 55M
Menu structure as in
Settings Options
ALT.PAYOUT enabled
TUBECOUNT COIN MECH contr.
MIXED PAYMENT allowed
MDB-comp.mode B.Pract.
SAVE SETTINGS yes

After pressing the "E" key
"done" stands for confirmation
in the display!

Settings in the installation menu
M - 7 - E
Menu structure as in
Settings Options
> CREDIT SYSTEM CRED. CONFIG. MAN.CONFIG.
> COIN MECHANISM TUBE COUNT by COINMECH
ALT. PAYOUT on
TUBES EMPTY INFO A
> CARD READER MIXED PAYM. on
MIXED PAYM.PRICE cash price
MDB-comp.mode Best Practice

Note:
The previously made settings must be checked again after a software update of the VMC.

Kreditanzeige bei Münzeinwurf sehr träge

Credit display very sluggish when inserting coins:

  1. Under: Menu ⇒ Installation ⇒ Deactivate card system 2
  2. Under: Menu ⇒ Installation ⇒ Special setting C,

set the MDB polling rate to 100ms or 50ms!

Adjust the MDB polling rate only in selected individual cases!
There may be problems with the display!

The table shows the bit mask for the desired settings, please set appropriately.

01 For cold water products, the cup price becomes 0.00
02 IR readout/configuration only active when entered in the menu level (no menu selected)
04 Output all error messages in clear text
08 pressure cell old (0.5 .. 4.5V
16 Water shortage detection deactivated via the measuring turbine (espresso machines)
32 BARISTA: When the milk cleaning time (Def. = 36h) is reached, the milk products are not taken out of service.
64 Reduce MDB polling rate to 100ms
128 Shorten MDB polling rate to 50ms, gains over 64

Software version / FTL

Display of the software status in the service menu: M - 8 - E - 21 - L

Software Patch menu FTL suitable Comment

Problemlösungen

Troubleshooting Overview