Apaul (Diskussion | Beiträge) |
Apaul (Diskussion | Beiträge) |
||
| Zeile 35: | Zeile 35: | ||
[[Sielaff software designations|What is behind the software name?]] | [[Sielaff software designations|What is behind the software name?]] | ||
''' | '''Software status:''' | ||
*Versions from 2012 support -Cash Sale- (coin payout) | *Versions from 2012 support -Cash Sale- (coin payout) | ||
| Zeile 73: | Zeile 73: | ||
| V50Dc613.pat | | V50Dc613.pat | ||
| {{Nein}} | | {{Nein}} | ||
| style="text-align:left" | | | style="text-align:left" | Minimum software status for current software updates | ||
|- | |- | ||
| V50Ec617.pat | | V50Ec617.pat | ||
| {{Nein}} | | {{Nein}} | ||
| style="text-align:left" | ''' | | style="text-align:left" | '''Preferred software version:'''<br>With older software, the machine could pay out the deposit twice! | ||
|- | |- | ||
| V50Gc224.pat | | V50Gc224.pat | ||
Version vom 25. Januar 2022, 11:50 Uhr
Back to Sielaff overview
Installation instructions
| File | User manual Vencube beta currently only in German |
|---|---|
| Download link | BA_Vencube_beta_032020.pdf |
Vencube assembly and commissioning
Mount the Vencube
Vencube Commissioning
- Turn on the machine.
- If necessary, adjust the Vencube using the Ventool.
- If necessary, configure the machine control and the payment systems.
You can find information on this in the wiki! - Wait until both LEDs turn green.
- Close the door.
- Test the machine by making a trial vend with change.
- Open the door again.
- Enter the data for VENSOFT (serial number, machine number).
- Perform a cash withdrawal by pressing the “E” button on the Vencube until you hear a beep.
- Close the door.
- Commissioning is complete.
|
Do not stick the VenCube antenna on the cable duct above or in the vicinity of the insertion chute, this will lead to disruptions in the bottle acceptance! |
Other notes:
- For cashless systems, depending on the manufacturer, an MDS extension must be used.
- A reed switch (magnetic switch) can also be used as an alternative to the switch. The reed switch should protrude 1-2 mm.
- Without a cashless system, the MDB slave interface remains unused, which is why LED1 on the VenCube will flash red twice, see Vencube beta Bedienungsanleitung.
|
|
|
|
Softwarestand / FTL
What is behind the software name?
Software status:
- Versions from 2012 support -Cash Sale- (coin payout)
- In the case of versions older than version
V50Dc613.pat, the aforementioned version must first be installed before a more recent software version can be installed. - Software version of the SiOne should be
V50Ec617.pat, with other software the machine could pay out the deposit twice.
Check software version:
| Action/Enter | Shown in the display |
|---|---|
| Open the machine door | Please close machine door!
|
| Use the M button to select SERVICE and confirm with the E button |
SERVICEMODE
|
| "Set the service key!" note. | Set the service key!
|
| Enter service number 21... | Enter service number 00
|
| ... and confirm with the L button. | Enter service number 21
|
| The software version is now displayed. | Software Machine:
|
| Software | FTL suitable | omment |
|---|---|---|
| V50Dc613.pat | Minimum software status for current software updates | |
| V50Ec617.pat | Preferred software version: With older software, the machine could pay out the deposit twice! | |
| V50Gc224.pat | ||
| V50Ic213.pat | ||
| V50Ic329.pat | ||
| V50xcxxx.pat |
Einstellungen der Steuerung
- Automatentyp: Sielaff RN SiOne mit Sielaff-Steuerung
Einstellungen mit Hopper
|
| ||||||||||||||||||||||||||||||||||||||||||||
Einstellungen mit Hopper und Karte oder Chip
|
| |||||||||||||||||||||||||||||||||
Einstellungen mit Karte oder Chip
|
| |||||||||||||||||||||||||||||||||